PLATINUM Series Temperature, Process and Strain Controllers
TheIndustry LeadingPLATINUM Series family of microprocessor-based PID controllers offer unparalleled flexibility in process measurement. While extremely powerful and versatile, great care has gone into designing a product that is very easy to set-up and use. The automatic hardware configuration recognition eliminates the need for jumpers and allows the firmware to automatically simplify itself, eliminating all menu options that do not apply to a specific configuration. Offered in 1⁄32, 1⁄16, and 1⁄8 DIN sizes, the 1⁄16 and 1⁄8 DIN models can be configured with dual displays, models are available with single and dual 4 digit displays or single 6 digit display.
Each unit allows the user to select the input type from 9 thermocouple type, Pt RTDs, thermistors, DC voltage, or DC current, and Strain & Bridge inputs. The full bidirectional voltage or current inputs are fully scalable to virtually all engineering units, with a selectable decimal point that is perfect for use with pressure, flow, or other process input.
Up to 6 programmable outputs and additional unique features make the PLATINUM Series"The Most Powerful"product in its class. Some of these additional standard features are: remote setpoint for cascaded control set-ups, high-high/low-low alarm functionality, external latch reset, external ramp and soak program initiation, combination heat/cool control mode, configuration save and transfer, and configuration password protection.
Free Downloadable Software (Upgraded Version is Available Now!)
Free Downloadable Configurator Windows® Application Software (Platinum Configurator and USB Driver)
Fully Configure all PLATINUM Functions/Parameters
Auto-Connect Through USB Channel
Load/Save PLATINUM Configuration Files
Performance Tracking (Charting) with Data Capture
An advanced multi-stage ramp and soak sequencer supports up to 99 profiles of 8 segment ramp/soak sequences. Profiles may be linked to provide extended sequences and auxiliary outputs may be triggered based on individual Ramp or Soak states to provide external control over blowers, mixers or other auxiliary control functions.
Embedded Ethernet and Serial Communications
Optional “embedded ethernet” on the 1⁄16 and 1⁄8 DIN models allow the units to connect directly to an Ethernet network and transmit data in standard TCP/IP packets, or serve Web pages over a LAN or the Internet. Optional serial communications are also available configurable as RS232 or RS485, with straightforward ASCII commands or MODBUS®. All three types of communications interfaces can be installed and active simultaneously.
LabVIEW™ Driver
The Platinum LabVIEW™ driver is the National Instrument device driver for communicating with Omega Platinum Controllers via Modbus RTU/ASCII and Modbus TCP protocols. The driver allows easy access to the internal data, configuration settings, and operating functions of the Platinum product family.
The LabVIEW™ instrument driver reduces the application development time and simplifies instrument control. With the Platinum LabVIEW driver, customers can quickly communicate with the instrument and develop robust test applications and software.
DasyLab
Support for the easy-to-useDasyLab softwaresolves complex data acquisition and control problems by allowing you to work with flowcharts directly on your PC screen. The high input accuracy, advanced process control, extended sequencing capability and flexible output options of a Platinum controller may be easily integrated with the rich set of function modules provide by the DasyLab software. The DasyLab software may be integrated thru the Platinum serial, Ethernet or USB connections.
*If you has the previous firmware version installed 1.3.0.25, please upgrade it to1.3.0.27.
Comparison ChartSee full comparison chart
Pt Series Features—Performance | Vs Competition | Benefits |
---|---|---|
Up to 20 Input Samples per Second with 24-bit ADC | Best in class | Improved control for responsive systems such as flow or weight control in factory automation and process industries. |
Up to 99 Programs with 16 Ramps and Soaks Including Ramp/Soak Events and Remote Start. Chainable for unmatched programmability. | Best in class | Combines with the measurement accuracy feature to provide precise control in menu-driven applications such as plastics, food, and ceramics processing. |
SPECIFICATIONS
INPUTS
Input Types:Thermocouple, RTD, Thermistor, Analog Voltage, Analog Current, Strain & Bridge Inputs
Current Input:4 to 20 mA, 0 to 24 mA scalable
Voltage Input:±100 mV, ±1 V, ±10 Vdc scalable
Thermocouple Input (ITS 90):K, J, T, E, R, S, B, C, N
RTD Input (ITS 90):100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100Ω only), or 0.003916 (100 Ω only) curves
Thermistor Input:2252 Ω, 5K Ω, 10K Ω
Strain Input:±100 mV, ±50 mV
Excitation:Firmware selectable (no jumpers to set) to 5, 10, 12, and 24 Vdc @ 25 mA (24V for AC Units Only)
Configuration:Differential
Polarity:Bipolar
Accuracy:See full table below
Resolution:0.1° temperature; 10 µV process
Input Impedances:
Process Voltage/Strain:10M Ω for ±100 mV, 1M Ω for other voltage ranges
Process Current:5 Ω
Thermocouple:10K Ω max
Auxiliary Input (Remote Setpoint):3.5K Ω for 0-10 V, 50K Ω for 0-1 V, 50 Ω for Current
Temperature Stability:
RTD:0.04°C/°C
Thermocouple @ 25°C (77°F):0.05°C/°C (cold junction compensation)
Process/Strain:50 ppm/°C
A/D Conversion:24-bit sigma delta
Reading Rate:20 samples per second
Digital Filter:Programmable from 0.05 seconds (filter = 1) to 6.4 seconds (filter = 128)
CMRR:120 dB
Setpoint Adjustment:4 Digit (-9999 to +9999 counts); 6 Digit (-99999 to +999999)
Warm-Up to Rated Accuracy:30 mins
Load Regulation:1.1%
CONTROL MODES
Action:Reverse (heat), direct (cool), or heat/cool
Auto-Tune:Operator initiated from front panel
Adaptive Tune:User selectable; fuzzy logic continuous PID tuning optimization
Control Modes:ON/OFF or the following time/amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative
Cycle Time:0.1 to 199 seconds
Ramp and Soak:Up to 99 saved ramp and soak programs, up to 8 ramp and 8 soak segments with individually selectable events per program
Ramp and Soak Segment Times:00.00 to 99.59 (HH:MM) or 00.00 to 99.59 (MM:SS)
CONTROL OUTPUTS
Analog Output:Non-isolated, programmable for control or retransmission; Voltage Output 0-10V output. 500Ohms Min. Accuracy 0.1%(1); Current Output 0-20mA output. 500Ohms Max. Accuracy 0.1%(1)(2); Step response time 100ms(3)
DC Pulse:Non-isolated; 10 Vdc at 20 mA
SPST Relay:Single pole, single throw mechanical relay, 250 Vac or 30 Vdc at 3 A (resistive load)
SPDT Relay:Single pole, double throw mechanical relay, 250 Vac or 30 Vdc at 3 A (resistive load)
SSR:20 to 265 Vac at 0.05 to 0.5 A (resistive load)
Isolated Analog:1.5kV Isolation(4), programmable for control or retransmission; Voltage Output 0-10V output. 500Ohms Min. Accuracy 0.1%(1); Current Output 0-20mA output. 500Ohms Max. Accuracy 0.1%(1)(2); Step response time 100ms(3)
Isolated DC Pulse:1.5kV Isolation(4); 10Vdc at 20mA
(1) At 25C.
(2) Output scaling required for stated accuracy. Refer to Platinum Current Output Application Note.
(3) Filter setting of 1.
(4) Isolated outputs not individually isolated.
COMMUNICATIONS (USB STANDARD, OPTIONAL SERIAL AND ETHERNET)
Connection:
USB:Female micro-USB
Ethernet:Standard RJ45
Serial:Screw terminals
USB:USB 2.0 host or device
Ethernet Standards Compliance:IEEE 802.3 10/100 Base-T autoswitching, TCP/IP, ARP, HTTPGET
Serial:Software selectable RS232 or RS485; programmable 1200 to 115.2 K baud
Protocols:Omega ASCII, Modbus® ASCII/RTU
ISOLATION
Approvals:UL, cUL, CE
Power to Input/Output:2300 Vac per 1 min test; 1500 Vac per 1 min test (low voltage/power option)
Power to Relays/SSR Outputs:2300 Vac per 1 min test
Relays/SSR to Relay/SSR Outputs:2300 Vac per 1 min test
RS232/RS485 to Inputs/Outputs:500 Vac per 1 min test
Input Type | Description | Range | Accuracy |
---|---|---|---|
Process/Strain | Process Voltage | ±50 mV, ±100 mV, ±1, ±10 Vdc | 0.03% FS |
Process | Process Current | Scalable within 0 to 24 mA | 0.03% FS |
J | Iron-Constantan | -210 to 1200°C (-346 to 2192°F) | 0.4°C (0.7°F) |
K | CHROMEGA®-ALOMEGA® | -270 to -160°C (-454 to -256°F) -160 to 1372°C (-256 to 2502°F) | 1.0°C (1.8°F) 0.4°C (0.7°F) |
T | Copper-Constantan | -270 to -190°C (-454 to -310°F) -190 to 400°C (-310 to 752°F) | 1.0°C (1.8°F) 0.4°C (0.7°F) |
E | CHROMEGA®-Constantan | -270 to -220°C (-454 to -364°F) -220 to 1000°C (-364 to 1832°F) | 1.0°C (1.8°F) 0.4°C (0.7°F) |
R | Pt/13%Rh-Pt | -50 to 40°C (-58 to 104°F) 40 to 1788°C (104 to 3250°F) | 1.0°C (1.8°F) 0.5°C (0.9°F) |
S | Pt/10%Rh-Pt | -50 to 100°C (-58 to 212°F) 100 to 1768°C (212 to 3214°F) | 1.0°C (1.8°F) 0.5°C (0.9°F) |
B | 30%Rh-Pt/6%Rh-Pt | 100 to 640°C (212 to 1184°F) 640 to 1820°C (1184 to 3308°F) | 1.0°C (1.8°F) 0.5°C (0.9°F) |
C | 5%Re-W/26%Re-W | 0 to 2320°C (32 to 4208°F) | 0.4°C (0.7°F) |
N | Nicrosil-Nisil | -250 to -100°C (-418 to -148°F) -100 to 1300°C (-148 to 2372°F) | 1.0°C (1.8°F) 0.4°C (0.7°F) |
RTD | Pt, 0.00385, 100 Ω, 500 Ω, 1000 Ω | -200 to 850°C (-328 to 1562°F) | 0.3°C (0.7°F) |
RTD | Pt, 0.003916, 100 Ω | -200 to 660°C (-328 to 1220°F) | 0.3°C (0.7°F) |
RTD | Pt, 0.00392, 100 Ω | -200 to 660°C (-328 to 1220°F) | 0.3°C (0.7°F) |
Thermistor | 2252 Ω | -40 to 120°C (-40 to 248°F) | 0.2°C (0.35°F) |
Thermistor | 5K Ω | -30 to 140°C (-22 to 284°F) | 0.2°C (0.35°F) |
Thermistor | 10K Ω | -20 to 150°C (-4 to 302°F) | 0.2°C (0.35°F) |
Accessories
Use the optional PT-USB-CABLE for a NEMA4 rated panel mount USB connector. A 12" (304mm) length cable connects from USB port of Platinum controller to your control panel. This accessory includes a protective end cap when not in use.
The PT-USB-ADAPTER, which is supplied with each unit, can be plugged into the controller and be used with a standard USB 2.0 memory stick.
This 1 GB USB thumbdrive has a standard USB connector on one end and a micro-USB connector on the other end. It is convenient for transferring files between your PC and your PLATINUM unit.
The part numbers listed below are only examples. Many more configurations are offered and can be constructed using the part number builder at the bottom of this page.